Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Filters








62 Hits in 7.6 sec

Research on Earth Resistivity Measuring and Modeling of HVDC Deep-well Grounding Electrode Sites

Maoheng Jing, Xishan Wen, Hansheng Cai, Yun Teng, Shangmao Hu, Yi Zhang, Lei Lan, Hailiang Lu
2020 IEEE Access  
deep layer and the vicinity of the electrode, and the earth resistivity model of deep-well grounding electrode is obtained.  ...  By comparing the on-site grounding resistance measurements of practical engineering application, it is found that the absolute error of the earth resistivity model obtained in this paper is 0.064 when  ...  To sum up, this paper adopts a new idea to solve the problem of DC deep-well grounding electrode site resistivity survey. III. HVDC DEEP-WELL GROUNDING ELECTRODE SITE RESISTIVITY SURVEY A.  ... 
doi:10.1109/access.2020.2968366 fatcat:6b2rk7vm3vhdlee6vdvyyqen7m

Adjustment of the geoelectric model for a ground electrode design – the case of the Rio Madeira HVDC transmission system, Brazil

Paulo E.F. Freire, Sueli Y. Pereira, Antonio L. Padilha
2021 Zenodo  
Abstract: The two ground electrodes of the south end of the Rio Madeira HVDC transmission system are located within the volcanic-covered Paraná basin, SE Brazil.  ...  The preliminary model is based on data acquired with shallow (electroresistivity) and deep (magnetotelluric) geophysical soundings.  ...  Ground electrodes of HVDC transmission systems provide a low resistance current return path during both monopolar and bipolar operation, using the earth as the conductive medium.  ... 
doi:10.5281/zenodo.4608512 fatcat:vmfmwl3lxjen3mpcpucofmkmee

Rio Madeira HVDC System: Commissioning of the Ground Electrode for Bipole 2 at Porto Velho

Paulo Freire, Jairo Kalife, Gil Oliveira
2022 Applied Sciences  
For the confirmation of the new site, it was built in the central area of the site, a single-well 47 m deep test electrode, interconnected to the original 15 km electrode line by an additional 40 km long  ...  However, the main objective of the paper is the evaluation of the electrode resistance, which is an essential HVDC electrode parameter.  ...  Therefore, the design of an HVDC ground electrode requires the construction of a deep geoelectric model, which, in the case of a high-resistivity subsurface, will comprise half Earth's crust.  ... 
doi:10.3390/app12073279 doaj:c223e88ec8614d9ab0b28e83cea6898b fatcat:fj6hhiguzzelnftennnkeesray

Long-term geomagnetically induced current observations in New Zealand: Earth return corrections and geomagnetic field driver

Daniel H. Mac Manus, Craig J. Rodger, Michael Dalzell, Alan W. P. Thomson, Mark A. Clilverd, Tanja Petersen, Moritz M. Wolf, Neil R. Thomson, Tim Divett
2017 Space Weather: The international journal of research and applications  
Currents of~30-50 A are observed, depending on the measurement location.  ...  However, after correcting for Earth return operation, as described here, the New Zealand measurements provide an unusually long and spatially detailed set of geomagnetically induced current (GIC) measurements  ...  This research was supported by the New Zealand Ministry of Business, Innovation and Employment Hazards and Infrastructure Research  ... 
doi:10.1002/2017sw001635 fatcat:kr56i5ic4vdmljfvxds7jbpwtu

Overview of Research Status of DC Bias and Its Suppression in Power Transformers

Youliang Sun, Li Zhang, Zhuangzhuang Zhang, Dong Wang
2022 Energies  
research on DC bias voltage and its suppression.  ...  Finally, the current research on DC bias voltage of power transformers is summarized, and the progress and deficiencies of current research are pointed out, which has certain reference value for future  ...  Research Status of the Generation Mechanism of DC Bias Research on Transformer DC Bias Phenomenon Caused by Ground Current in HVDC Projects The research on the distribution mechanism of the ground current  ... 
doi:10.3390/en15238842 fatcat:mqqdqlzdmbgy7g2cwhrn55zu3u

Alternative Simplified Analytical Models for the Electric Field, in Shoreline Pond Electrode Preliminary Design, in the Case of HVDC Transmission Systems

George J. Tsekouras, Vassiliki T. Kontargyri, John M. Prousalidis, Fotios D. Kanellos, Constantinos D. Tsirekis, Konstantinos Leontaritis, John C. Alexandris, Panagiota M. Deligianni, Panagiotis A. Kontaxis, Antonios X. Moronis
2022 Energies  
the preliminary study to be conducted swiftly, giving satisfactory results about electric field gradient, ground potential rise and resistance to remote earth of electrodes stations for the near and far  ...  In this research, a two-step modification of the CIGRE simplified model was proposed.  ...  The authors are grateful to Spyridon Gialampidis for his work on the original text version. Conflicts of Interest: The authors declare no conflict of interest.  ... 
doi:10.3390/en15176493 fatcat:4kshd7btvredbkg3t7tzlqrwoi

Evaluation, Analysis and Diagnosis for HVDC Transmission System Faults via Knowledge Graph under New Energy Systems Construction: A Critical Review

Jiyang Wu, Qiang Li, Qian Chen, Guangqiang Peng, Jinyu Wang, Qiang Fu, Bo Yang
2022 Energies  
Based on the prior research on fault diagnosis methods of HVDC systems, this work comprehensively summarizes and analyzes the existing fault diagnosis methods from three different angles: fault type, fault  ...  To ensure the operation reliability of the power grid and reduce the outage time, it is imperative to realize fault diagnosis of HVDC transmission systems in a short time.  ...  The simulation model of VSC-HVDC can be divided into the device detailed model, device simplified model, variable resistance model, and average value model.  ... 
doi:10.3390/en15218031 fatcat:ljvg5vwhkjd4pm7wpr4kmtamzq

Issues and Challenges for HVDC Extruded Cable Systems

Giovanni Mazzanti
2021 Energies  
Therefore, the contribution this paper aims at giving is a systematic, comprehensive and updated summary of the main present and future issues and challenges that HVDC cable systems have to face to further  ...  The topics covered in this review–treated in alphabetical order for the reader's convenience–are accessories, higher voltage and power, laying environment (submarine and underground cables), modeling,  ...  Funding: This research received no external funding. Conflicts of Interest: The authors declare no conflict of interest.  ... 
doi:10.3390/en14154504 fatcat:yi6cebrolvcjvdvh2xtarbaria

Hydrological Studies In India During Last Decade: A Review

Tanvi Arora, V. M. Tiwari
2018 Proceedings of the Indian National Science Academy  
This article provides a glimpse of some of these studies carried out by Indian researchers in the last one decade in field of Geomagnetism and Aeronomy.  ...  IAGA, the International Association of Geomagnetism and Aeronomy, one of the eight Associations of the IUGG, is dedicated to the promotion of international research cooperation in the field of Geomagnetism  ...  Archana Bhattacharyya and B.R. Arora, and Drs. M. Ravi Kumar, Team-IIG, B.P.K. Patro, Kusumita Arora, and Gautam Rawat are gratefully acknowledged for providing valuable inputs for the article.  ... 
doi:10.16943/ptinsa/2018/49512 fatcat:o3fie6eynfhyznxbm2r4tzvtri

Table of Contents

2020 2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)  
1084 Recommended volt ampere characteristics of MOA in the lightning invasion overvoltage calculation of UHV AC Substation and its influence on simulation results CHEN, Xiujuan IEEE 1085 Probability analysis  ...  of system special operation mode in the lightning invasion overvoltage calculation of UHV AC Substation CHEN, Xiujuan  ...  chain Yang, Xiong;Li, Wendong;Wang, Chao;Jiang, Zhihui;Chen, Mingyu;Zhang, Guanjun IEEE 10142 Performance Testing and Analysis of HVDC Deep-well Grounding Electrode Hu, Shangmao;Cai, Hansheng;  ... 
doi:10.1109/ichve49031.2020.9279428 fatcat:mrin4cgjy5frbgtbst7jnibwrm

The Role of Global/Regional Earth Conductivity Models in Natural Geomagnetic Hazard Mitigation

Anna Kelbert
2019 Surveys in geophysics  
The strength of the GICs that flow through a transformer depends on multiple factors, including the spatiotemporal signature of the geomagnetic disturbance, the geometry and specifications of the power  ...  The phenomena of extreme geomagnetic disturbances, including storms and substorms, and their effects on human activity are commonly referred to as geomagnetic hazards.  ...  Slate, and the anonymous reviewer for their valuable comments on a draft manuscript.  ... 
doi:10.1007/s10712-019-09579-z fatcat:n46p2lcqyzbfliq25lpojzpreu

The coming of Age of HVDC extruded power cables

John C Fothergill
2014 2014 IEEE Electrical Insulation Conference (EIC)  
The paper gives a personal perspective on the development of these cables and links it with the author's research over the last 30 years.  ...  Techniques for measuring space charge and conduction are described and discussed in terms of how they might be used to quantify the state of a HVDC cable.  ...  The peeling is 150 m and the earthed side of the sample is found on the left hand side where the measured charge is negative. On the right there are two positive peaks.  ... 
doi:10.1109/eic.2014.6869361 fatcat:cg3kxuyf2vb7da4t527gvnvzbu

Failure of submarine cables used in high‐voltage power transmission: Characteristics, mechanisms, key issues and prospects

Weiwang Wang, Xilin Yan, Shengtao Li, Lina Zhang, Jun Ouyang, Xianfeng Ni
2021 IET Generation, Transmission & Distribution  
This study reviews the failure of high-voltage submarine cables used in offshore power transmission and provides highlights of their failure characteristic, mechanisms, key issues and prospects.  ...  Inevitably, the fault occurs in HV submarine cables that is different from that of an underground cable. External aggression remains the primary cause of faults, such as fishing and anchors.  ...  Seasonal factors such as soil temperature, thermal resistivity of the soil and daily load cycles were considered in the electrothermal life model.  ... 
doi:10.1049/gtd2.12117 fatcat:54qntywp4zaybfjk6b6peh5kbe

Insulator aging tests with HVAC and HVDC excitation using the tracking wheel tester

J P Holtzhausen, P J Pieterse, H J Vermeulen, S Limbo
2010 2010 International Conference on High Voltage Engineering and Application  
Site severity class The site severity class can be obtained from the surface deposit and dust gauge measurements [1] .  ...  A measured NSDD value above 2 [ 2 cm mg ] requires an increase by one level for the site severity class.  ... 
doi:10.1109/ichve.2010.5640730 fatcat:44rhxhepkjfm5h4yqrpmfsqmni

Numerical simulation of the cathodic protection of pipeline networks under various stray current interferences [chapter]

L. Bortels, J. Deconinck
2005 Modelling of Cathodic Protection Systems  
The software can deal with all standard kinds of cathodic protection interferences as well as stray currents coming from other CP-installations, DC-traction systems, HVDC-transmission lines, grounding  ...  As a result, the model gives the 'on' and 'off' potential along the pipe, the potential distribution in the soil, the axial currents flowing through the pipes as well as the radial current densities leaving  ...  Also, a model can provide reference values for measurements on operational sites, that can help in the tracing and solving of any possible anomaly.  ... 
doi:10.2495/1-85312-889-9/08 fatcat:3so6dmvnrjgv7mutenqwulrdae