Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Filters








8,216 Hits in 4.7 sec

MRI reconstruction using real-time motion tracking: A simulation study

Jeff Orchard, Robert Staruch
2008 2008 42nd Asilomar Conference on Signals, Systems and Computers  
Using a simulated MRI scanner, we compare the different ways to use the motion-tracking data (both retrospectively and prospectively) and compare the reconstruction results to motion compensation using  ...  Previous efforts to compensate for patient motion in MRI invariably assume that the patient is motionless for some part of the scan.  ...  ACKNOWLEDGMENT The authors thank the Montreal Neurological Institute for the use of their BrainWeb data.  ... 
doi:10.1109/acssc.2008.5074761 fatcat:kmuyg4lnejezrp4mel54ze6rpq

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Manoj Sarma, Peng Hu, Stanislas Rapacchi, Daniel Ennis, Albert Thomas, Percy Lee, Patrick Kupelian, Ke Sheng
2014 International Journal of Radiation Oncology, Biology, Physics  
Purpose-To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking.  ...  Methods and Materials-Seven retrospective lung cancer patients were included in the simulation study.  ...  Acknowledgments The study was supported in part by National Institutes of Health grants R21CA161670 and R21CA144063.  ... 
doi:10.1016/j.ijrobp.2013.11.217 pmid:24412430 pmcid:PMC3941205 fatcat:fi3id4rdszbcjl6rqhpqui6vgy

MR-based motion correction for cardiac PET parametric imaging: a simulation study

Rong Guo, Yoann Petibon, Yixin Ma, Georges El Fakhri, Kui Ying, Jinsong Ouyang
2018 EJNMMI Physics  
"MR-based motion correction for cardiac PET parametric imaging: a simulation study." EJNMMI Physics 5 (1): 3.  ...  The aim of this study was to perform a realistic positron emission tomography-magnetic resonance (PET-MR) simulation study using 4D XCAT to evaluate the impact of MR-based motion correction on the estimation  ...  Availability of data and materials Please contact the corresponding author, Jinsong Ouyang (ouyang.jinsong@mgh.harvard.edu), for the data used in this manuscript.  ... 
doi:10.1186/s40658-017-0200-9 pmid:29388075 pmcid:PMC5792384 fatcat:xz2j5twzszaa3kisooib6jch7u

Adapting to the motion of multiple independent targets using multileaf collimator tracking for locally advanced prostate cancer: Proof of principle simulation study

Emily A Hewson, Yuanyuan Ge, Ricky O'Brien, Stephanie Roderick, Linda Bell, Per R Poulsen, Thomas Eade, Jeremy T Booth, Paul J Keall, Doan T Nguyen
2020 Medical Physics (Lancaster)  
This study developed a multileaf collimator (MLC) tracking algorithm for differential motion adaptation and evaluated it in simulated treatments of locally advanced prostate cancer.  ...  The dosimetric error was estimated by calculating the dose delivered to the prostate, lymph nodes, bladder, rectum, and small bowel with a motion-encoded dose reconstruction method.  ...  ACKNOWLEDGMENTS The authors acknowledge the support of a Cancer Council NSW Project Grant. PJK acknowledges an Australian Government NHMRC Senior Principal Research Fellowship.  ... 
doi:10.1002/mp.14572 pmid:33124079 fatcat:iawxxptipnhdbjnl46ywpf4c3i

SMART tracking: Simultaneous anatomical imaging and real-time passive device tracking for MR-guided interventions

Frank Zijlstra, Max A. Viergever, Peter R. Seevinck
2019 Physica medica (Testo stampato)  
This study demonstrates a proof of concept of a method for simultaneous anatomical imaging and real-time (SMART) passive device tracking for MR-guided interventions.  ...  The average pairwise error between the MRI and CT locations was 0.30 mm for tracking of stationary steel spheres and 0.29 mm during motion.  ...  DISCUSSION In this study, we have demonstrated SMART tracking, a passive tracking framework that allows real-time tracking of metal devices in 2D MRI at a rate of 10 updates per second, while also providing  ... 
doi:10.1016/j.ejmp.2019.07.019 pmid:31515028 fatcat:5okkcgft65hwlk46srv6b2n5ue

Track H

2014 Biomedical Engineering  
A few installations with a combination of radiotherapy delivery and simultaneous MRI, PET online control during heavy-ion treatment or telerobotic ultrasound systems for realtime detection of target motion  ...  In the management of organ motion a 4D-imaging is necessary, realized as 4D-CT or list mode (PET).  ...  In cooperation with the Westphalian University of Applied Sciences, we are developing a method for biopsies guided by real-time MRI, where the MR image artefact of the biopsy needle is used for needle  ... 
doi:10.1515/bmt-2014-5007 pmid:25385892 fatcat:xcjcbtnayvfyzhaaaa4askc5qi

Deep Predictive Motion Tracking in Magnetic Resonance Imaging: Application to Fetal Imaging [article]

Ayush Singh, Seyed Sadegh Mohseni Salehi, Ali Gholipour
2020 arXiv   pre-print
To help build automatic MRI motion tracking and navigation systems to overcome the limitations of the current process and improve fetal imaging, we have developed a new real time image-based motion tracking  ...  Our real-time deep predictive motion tracking technique can be used to assess fetal movements, to guide slice acquisitions, and to build navigation systems for fetal MRI.  ...  for use in real-time applications, such as motion tracking for real-time navigation.  ... 
arXiv:1909.11625v2 fatcat:hpxqe67345arboa5jg6oyqrjhi

A 5D computational phantom for pharmacokinetic simulation studies in dynamic emission tomography

Fotis A. Kotasidis, Charalampos Tsoumpas, Irene Polycarpou, Habib Zaidi
2014 Computerized Medical Imaging and Graphics  
Methods: A new 5D anthropomorphic digital phantom was developed based on a generic simulation platform, for accurate parametric imaging simulation studies in emission tomography.  ...  The phantom is based on high spatial and temporal information derived from real 4D MR data and a detailed multi-compartmental pharmacokinetic modelling simulator.  ...  Similarly, dynamic MRI has also been used to derive the motion information, which is then used in a four-dimensional (4-D) simulation framework [14, 15] .  ... 
doi:10.1016/j.compmedimag.2014.06.018 pmid:25082066 fatcat:b222ou43nnf4lpzkthmokp27xe

Track O. Image Computing

P. Suhail Parvaze, S. Ramakrishnan
2016 Biomedical Engineering  
The images display strong differences depending on the system matrix used. Thus, we studied the influence of the Tikhonov regularization by removing it and using a different reconstruction approach.  ...  Images of the phantom were reconstructed with the two different system functions using a Tikhonov regularization scheme with a fixed parameter and a modified Kaczmarz algorithm.  ...  The registered time-series was then again used to generate a VT which resulted in a motion reduction in every step.  ... 
doi:10.1515/bmt-2016-5013 pmid:27682695 fatcat:chpj7omugjbi5pisvul6xjhz7m

Prospective motion correction using tracking coils

Lei Qin, Ehud J. Schmidt, Zion Tsz Ho Tse, Juan Santos, William S. Hoge, Clare Tempany-Afdhal, Kim Butts-Pauly, Charles L. Dumoulin
2012 Magnetic Resonance in Medicine  
platform simulating both respiratory and cardiac motion.  ...  We developed prospective motion correction techniques for intra-cavity imaging using an array of tracking coils.  ...  Acknowledgments This study was supported by NIH P41 RR019703, R01 CA11288, R01 CA111981-01, as well as AHA 10SDG261039.  ... 
doi:10.1002/mrm.24310 pmid:22565377 pmcid:PMC3416927 fatcat:cg5tevcflnd4ddvp74oy6qbgky

Session 30: Radiation therapy IV – Tracking

Anna Arns, Jens Fleckenstein, Frank Schneider, Volker Steil, Frederik Wenz, Hansjoerg Wertz
2017 Biomedical Engineering  
An inhomogeneous thorax phantom with four different tumormimicking inlays was used to simulate a lung cancer patient.  ...  A comparison study between faster CBCT (18°/s) and conventional, clinical CBCT (3°/s) was performed to evaluate dose exposure and image quality.  ...  We developed a 4D dose recalculation workflow to simulate the dose delivered to a moving target volume.  ... 
doi:10.1515/bmt-2017-5051 fatcat:3dekmkkjrfgkdij5juu4fi33ta

Bone Motion Analysis from Dynamic MRI: Acquisition and Tracking [chapter]

Benjamin Gilles, Rosalind Perrin, Nadia Magnenat-Thalmann, Jean-Paul Vallée
2004 Lecture Notes in Computer Science  
We introduce a tracking algorithm based on 2D/3D registration and a procedure to validate the technique by using both dynamic and sequential MRI.  ...  As a case study, we apply this methodology on the human hip joint.  ...  We introduce a new technique to track bone motion automatically from real-time dynamic MRI based on the combination of temporal information of dynamic MRI and spatial information of static MRI by 2D/3D  ... 
doi:10.1007/978-3-540-30136-3_114 fatcat:55u3eep3mve43essieztxom4by

Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning

Seyoun Park, Rana Farah, Steven M Shea, Erik Tryggestad, Russell Hales, Junghoon Lee
2018 Physics in Medicine and Biology  
In this study, we propose a method to simultaneously track the lung tumor and external surrogates to evaluate their spatial correlation in a quantitative way using dynamic MRI, which allows real-time acquisition  ...  A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and groupwise registration.  ...  Although real-time tumor tracking is not the goal of this study, the computation time can be further reduced by incorporating a motion prediction algorithm (Verma et al 2011) into the tracking and optimizing  ... 
doi:10.1088/1361-6560/aaa20b pmid:29243669 pmcid:PMC5788465 fatcat:kbx7ozezlrbxpas6ukephxbzzq

Static compressive tracking

D. J. Townsend, P. K. Poon, S. Wehrwein, T. Osman, A. V. Mariano, E. M. Vera, M. D. Stenner, M. E. Gehm
2012 Optics Express  
Using two amplitude masks and a standard focal plane array, the system captures many projections simultaneously, avoiding the need for time-sequential measurements of a single scene.  ...  Scenes with few moving targets on static backgrounds have frame differences that can be reconstructed using sparse signal reconstruction techniques in order to track moving targets.  ...  For motion tracking purposes, we classify errors into three categories.  ... 
doi:10.1364/oe.20.021160 pmid:23037240 fatcat:5yhd75zvpng6jd4hsjm4rjpg7m

Quantifying ITV instabilities arising from 4DCT: a simulation study using patient data

Sara St. James, Pankaj Mishra, Fred Hacker, Ross I Berbeco, John H Lewis
2012 Physics in Medicine and Biology  
These fiducial locations are used in a simulation of a four-slice CT scanner to generate the ITV for 10, 20 and 30 mm diameter model tumours.  ...  In this work, we use the locations of gold fiducial markers implanted in lung tumours of eight patients to represent tumour motion.  ...  This was a geometric study and image reconstruction was not used.  ... 
doi:10.1088/0031-9155/57/5/l1 pmid:22343122 pmcid:PMC3358004 fatcat:bhxcoqcavnhihdhkc67tpuxvlq
« Previous Showing results 1 — 15 out of 8,216 results