Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Filters








10,689 Hits in 4.6 sec

Dual Attention Network for Heart Rate and Respiratory Rate Estimation [article]

Yuzhuo Ren, Braeden Syrnyk, Niranjan Avadhanam
2021 arXiv   pre-print
We propose a convolutional neural network which leverages spatial attention and channel attention, which we call it dual attention network (DAN) to jointly estimate heart rate and respiratory rate with  ...  Heart rate and respiratory rate measurement is a vital step for diagnosing many diseases.  ...  Our proposed dual attention network structure can be used to estimate Blood Volume Pulse (BVP) for heart rate estimation or respiratory wave for respiratory rate estimation individually.  ... 
arXiv:2111.00390v1 fatcat:rri2eapqtvdhjfhkw3b3xnm22u

Dual-Lead 55 mm Impedance Pneumography

Michael Klum, Mike Urban, Alexandru-Gabriel Pielmus, Reinhold Orglmeister
2020 Current Directions in Biomedical Engineering  
Based on our recent work on wearable IP, we propose a dual-lead, wearable IP setup with 55 mm electrode spacing to estimate respiratory flow and rate (RR).  ...  AbstractIn recent years, respiratory monitoring has gained attention due to the high prevalence and severe consequences of sleep apnea, post-anesthesia respiratory instability and respiratory diseases.  ...  Ethical approval: The research is approved by the TU Berlin Ethics Committee of the Department of Psychology and Ergonomics under the tracking number KL\_01\_20180117.  ... 
doi:10.1515/cdbme-2020-3052 fatcat:mwg72bdqefhzfjvn7dqjccvx6y

Estimation of vital signs from facial videos via video magnification and deep learning

Bin Lin, Jing Tao, Jingjing Xu, Liang He, Nenrong Liu, Xianzeng Zhang
2023 iScience  
Then, the steady part of the wave of each processed ROI is used for the extraction of features including heart rate, PTT, and features of pulse wave waveform.  ...  To solve the common problems of rPPG including weak extracted signals, body movements, and generalization with limited data resources, we proposed a dual-path estimation method based on video magnification  ...  network with a 3D-CBAM attention mechanism (CDCA-rPPGNet) for robust heart rate measurement.  ... 
doi:10.1016/j.isci.2023.107845 pmid:37790274 pmcid:PMC10542939 fatcat:c5oyvs72gnajbfts7jp32e2mcm

Dual-task performance in multimodal human-computer interaction: a psychophysiological perspective

Domen Novak, Matjaž Mihelj, Marko Munih
2010 Multimedia tools and applications  
Heart rate, skin conductance, respiration and peripheral skin temperature were recorded in addition to objective performance measures and self-report questionnaires.  ...  Analysis of psychophysiological responses found significant changes from baseline for both single-task and dual-task conditions.  ...  The work was funded by the EU Information and Communication Technologies Collaborative Project MIMICS grant 215756 and additionally supported by the Slovenian Research Agency.  ... 
doi:10.1007/s11042-010-0619-7 fatcat:2yi3sqvdtngqraav6hhpfhk33y

Intelligent Prediction and Optimization Algorithm for Chronic Disease Rehabilitation in Sports Using Big Data

Xuelei Zhang, Xiaofeng Wang
2021 Journal of Healthcare Engineering  
Using big data and deep learning (DL) in the sports domain, we propose a novel and intelligent prediction system for chronic diseases.  ...  We explore the fundamental causes for the diversified needs and insufficient supply of chronic disease patients in professional medical services and daily care.  ...  Inspired by the deep neural networks, we use a dual network tracking framework of the layered attention mechanism.  ... 
doi:10.1155/2021/9920421 pmid:34007431 pmcid:PMC8110381 fatcat:q3xic743uraoregeu26b2obpry

Physiological Parameters Monitoring System for Occupational Safety

R. Lukocius, M. Vaitkunas, J. A. Virbalis, A. Dosinas, A. Vegys
2014 Elektronika ir Elektrotechnika  
Index Terms-ECG, heart rate, inductive plethysmography, respiratory rate, remote monitoring.  ...  Remote computer evaluates one's health condition by tracking the abnormal deviations of the two main physiological parameters -heart rate and respiratory rate.  ...  The basic accuracy of the monitor is 1 % for heart rate estimation and 2 % for respiratory rate estimation.  ... 
doi:10.5755/j01.eee.20.5.7100 fatcat:ei5rtua52zckvor3gfw277hjvu

Spatial heterogeneity of the relation between resting-state connectivity and blood flow: An important consideration for pharmacological studies

Najmeh Khalili-Mahani, Matthias J. van Osch, Mark de Rooij, Christian F. Beckmann, Mark A. van Buchem, Albert Dahan, Johannes M. van Gerven, Serge A.R.B. Rombouts
2012 Human Brain Mapping  
We tested this hypothesis by examining the relation between CBF and resting-state-network consistency (RSNC)-representing average intranetwork connectivity, determined from dual regression analysis with  ...  Overall, we observed spatially heterogeneous relations between RSNC and CBF, and between the experimental factors (drug-by-time, time, drug and physiological rates) and each of these metrics.  ...  ACKNOWLEDGMENTS The authors thank Evelinda Baerends and Remco Zoethout for the study design and execution; and Jordan Gross and Rene Post (CHDR) for assisting with the data acquisition.  ... 
doi:10.1002/hbm.22224 pmid:23281174 fatcat:6bs6ie6yiba7dondlbp2dsmpzy

Health sensing by wearable sensors and mobile phones: A survey

Lei Song, Yongcai Wang, Ji-Jiang Yang, Jianqiang Li
2014 2014 IEEE 16th International Conference on e-Health Networking, Applications and Services (Healthcom)  
attentions.  ...  To tease out the technology advantages that address these challenges and diversities, this paper presented a survey on the state of the art of health sensing technologies using body sensor networks and  ...  Via measuring body sound at the neck using continuous wavelet transformation, the heart rate and respiratory rate were estimated. Villalba et al.  ... 
doi:10.1109/healthcom.2014.7001885 dblp:conf/healthcom/SongWYL14 fatcat:yaf6xuig3jhpba2kipoelbxj5i

Combining Visible Light and Infrared Imaging for Efficient Detection of Respiratory Infections such as COVID-19 on Portable Device [article]

Zheng Jiang, Menghan Hu, Lei Fan, Yaling Pan, Wei Tang, Guangtao Zhai, Yong Lu
2020 arXiv   pre-print
Then, a bidirectional GRU neural network with attention mechanism is applied to the respiratory data to obtain the health screening result.  ...  In this work, we perform the health screening through the combination of the RGB and thermal videos obtained from the dual-mode camera and deep learning architecture.We first accomplish a respiratory data  ...  So far, thermal imaging has been used as a monitoring technology in a wide range of medical fields such as estimations of heart rate [10] and breathing rate [11] [12] [13] .  ... 
arXiv:2004.06912v1 fatcat:7bth6zqn35ajdcpoqcwwqkkuiq

Hemodynamic Monitoring in Acute Care

2020 Biomedical Engineering  
These changes are parametrized and fed into regression models, estimating the original blood pressure.  ...  of unimodal pulse waves can enable noninvasive, continuous blood pressure estimation for cases where arterial catheterization is not justified.  ...  We propose a dual-lead, wearable IP setup with 55 mm electrode spacing to estimate respiratory flow and rate (RR).  ... 
doi:10.1515/bmt-2020-6020 pmid:33578464 fatcat:3filzu6asvfnpfr5mwg36zhdlm

Alterations in autonomic tone during trauma exposure using eye movement desensitization and reprocessing (EMDR)—Results of a preliminary investigation

Martin Sack, Wolfgang Lempa, Adrian Steinmetz, Friedhelm Lamprecht, Arne Hofmann
2008 Journal of Anxiety Disorders  
Onset of every stimulation/exposure period (n = 811) was marked and effects within and across stimulation sets on heart rate (HR), heart rate variability (HRV), pre-ejection period (PEP) and respiration  ...  EMDR combines stimuli that evoke divided attention -e.g. eye movements -with exposure to traumatic memories.  ...  HR = heart rate, RMSSD = root mean square of successive differences, PEP = pre-ejection period, RESP = respiration frequency.  ... 
doi:10.1016/j.janxdis.2008.01.007 pmid:18314305 fatcat:gr7omg5vvbeq5moc4x5ce3pai4

Considerations in the assessment of heart rate variability in biobehavioral research

Daniel S. Quintana, James A. J. Heathers
2014 Frontiers in Psychology  
Firstly, both breathing and blood pressure regulation have their own relationship to social, emotional, and cognitive experiments -if this is the case are we observing heart rate (HR) changes as a consequence  ...  Heart rate variability (HRV) refers to various methods of assessing the beat-to-beat variation in the heart over time, in order to draw inference on the outflow of the autonomic nervous system.  ...  ACKNOWLEDGMENTS The authors thank Maja Elstad, Tobias Kaufmann, and Douglas Angus for helpful comments on an earlier version of this manuscript.  ... 
doi:10.3389/fpsyg.2014.00805 pmid:25101047 pmcid:PMC4106423 fatcat:ujwf3zul2ra77gmsvzgh4hffbe

Device Sensing: Sensors and Algorithms for Pacemakers and Implantable Cardioverter Defibrillators

K. Kaszala, K. A. Ellenbogen
2010 Circulation  
At the beginning of exercise, minute ventilation (the product of tidal volume and respiratory rate) but not respiratory rate increases proportionately to the workload and oxygen consumption.  ...  Sensors for Rate Modulation Rate Modulation Studies in the 1970s demonstrated that adequate cardiac output during exercise predominantly relies on increases in heart rate, 5 especially if cardiac dysfunction  ...  Acknowledgments We would like to thank Richard Troughton, MB ChB, PhD, FRACP, and Iain C. Melton, MB ChB, FRACP, Christchurch, New Zealand,  ... 
doi:10.1161/circulationaha.109.919704 pmid:20876446 fatcat:zqexaok2lbhutivf577olb5fqm

IEEE Access Special Section Editorial: Advanced Information Sensing and Learning Technologies for Data-Centric Smart Health Applications

Qingxue Zhang, Vincenzo Piuri, Edward A. Clancy, Dian Zhou, Thomas Penzel, Wenchuang Walter Hu
2021 IEEE Access  
He has worked in industry for medical instrumentation and analysis companies interested in EMG, EEG, ECG and blood pressure, and the defense industry (aircraft instruments and radar).  ...  His research interests include signal processing, stochastic estimation, applied system identification, and instrumentation, particularly applied to problems in medical engineering and human rehabilitation  ...  and heart rate.  ... 
doi:10.1109/access.2021.3057527 fatcat:fpjlv5c4qfbdnp5aroj2srsqhq

2021 Index IEEE Journal of Biomedical and Health Informatics Vol. 25

2021 IEEE journal of biomedical and health informatics  
Departments and other items may also be covered if they have been judged to have archival value. The Author Index contains the primary entry for each item, listed under the first author's name.  ...  The primary entry includes the coauthors' names, the title of the paper or other item, and its location, specified by the publication abbreviation, year, month, and inclusive pagination.  ...  ., +, JBHI June 2021 2162-2171 Neonatal Heart and Lung Sound Quality Assessment for Robust Heart and Breathing Rate Estimation for Telehealth Applications.  ... 
doi:10.1109/jbhi.2022.3140980 fatcat:ufig7b54gfftnj3mocspoqbzq4
« Previous Showing results 1 — 15 out of 10,689 results